Torrent Electricals Ltd

RCCB

Residual Current Circuit Breakers

RCCB product image
  1. Home
  2. Switchgear
  3. RCCB

A Residual Current Circuit Breaker (RCCB) switch protects individuals and equipment from electric shocks and leaking currents. Also called a residual-current circuit breaker, it continuously monitors the flow of electricity and quickly cuts off power if it detects a problem. Used in homes, businesses and factories, RCCBs help keep the power supply safe and reliable.

Torrent Electricals offers a reliable range of RCCB switches made for quick response, accuracy, and lasting use. Built to meet current safety standards, these devices effectively protect against ground faults, reducing the risk of electrical hazards and making systems safer overall.

Contact Us

Certifications

Torrent Electricals Ltd. ISO45001

Torrent Electricals Ltd. ISO45001

Torrent Electricals Ltd. ISO14001

Torrent Electricals Ltd. ISO14001

Torrent Electricals Ltd. ISO9001

Torrent Electricals Ltd. ISO9001

Standards

IEC 61008-1

IEC 61008-1

2 Years Warranty

2 Years Warranty

Technical Specifications

CHARACTERISTICSTEL RCCB
Standard ConformityIS 12640-1:2016/ IEC 61008-1
Residual tripping characteristicsAC
Tripping Time At (IΔn)
Instantaneous<40 ms
Selective>150 ms
Rated current25, 32, 40, 63 A
Rated residual current30mA, 100mA, 300mA
Breaking capacity10kA
Calibration Temperature30°C
Rated Voltage UN
2P AC240 V
4P AC415 V
Frequency50 Hz
Maximum service voltage Ubmax2P = 265V / 4P = 455V
Minimum service voltage Ubmin2P = 100V / 4P = 190V
Power Supply
Rated making and breaking capacityupto 40A~500A (63A and above 10In)
Residual making and breaking capacityupto 40A~500A (63A and above 10In)
Conditional short-circuit capacity6000 Fuse 100A gL/gG
Conditional residual short-circuit capacity6000 Fuse 100A gL/gG
Grid distance35 mm
Isolator applicationYes
Insulation Degree
Insulation voltage660V (DC)
Shock Voltage6kV
Insulation Resistance1000 mΩ
Dielectric strength2.5 kV
Shock Resistance18 shocks 5 ms
Vibration Resistance3g
Endurance
Electrical at Un, In10000
Mechanical at Un, In20000
Protection degree with doorIP 20
Self extinguish degree (acc to UI94)V2
Tropicalisation (acc to EN/IEC 60068-2)+55°C / 95%RH
Pollution degree (acc EN/IEC 60947-1)2
Operating temperature-50°C to +60°C
Storage temperature-50°C to +60°C
Weight2P - 224.5g, 4P - 409g
Terminal Capacity
Rigid cable min/max (top)1.5/25 mm²
Flexible cable min/max (top)1.5/25 mm²
Rigid cable min/max (bottom)1.5/25 mm²
Flexible cable min/max (bottom)1.5/25 mm²
Busbars systemsBusbars systems
PinYes
ForkYes
CE MarkingYes

Salient Features

IP 20

IP 20

No Nuisance Tripping

No Nuisance Tripping

Fire Resistant

Fire Resistant

Padlocking Facility

Padlocking Facility

User Friendly Test Button

User Friendly Test Button